VELP MACRO CHNS ANALYZER
✓ The EMA 402XL is World’s first macro elemental analyzer for the simultaneous determination of C, H, N & S in a single configuration.
✓ The integrated 100-position electronic autosampler.
✓ EMA 402XL is a dynamic, reagent-free vertical furnace, reaching up to 1350 °C.
✓ Carbon, Hydrogen, and Sulfur are quantified using separate NDIR detector.
✓ Nitrogen is measured by a Thermal Conductivity Detector (TCD).
✓ Direct analysis of extra-large solid or liquid samples up to 3 grams.
VELP EMA 402XL Macro CHNS Analyzer
The VELP EMA 402XL Macro CHNS Analyzer is a high-performance elemental analysis system designed for the simultaneous determination of Carbon (C), Hydrogen (H), Nitrogen (N), and Sulfur (S) in a single configuration. Developed for laboratories that work with large and demanding solid or liquid samples, the EMA 402XL combines high-temperature combustion technology, advanced detection systems, and automated sample handling to provide an efficient and reliable solution for macro elemental analysis.
With its ability to directly analyze extra-large solid or liquid samples up to 3 grams, the EMA 402XL is particularly suitable for laboratories requiring high sample capacity and efficient analysis without the need for extensive sample preparation.
Advanced Macro Elemental Analysis
The EMA 402XL is designed as a macro elemental analyzer capable of simultaneously determining C, H, N, and S within a single analytical configuration. This integrated approach allows laboratories to perform multiple elemental determinations efficiently while simplifying the overall analytical workflow.
The analyzer is designed for applications where accurate elemental composition data is required for research, quality control, characterization, and routine laboratory analysis.
Integrated 100-Position Electronic Autosampler
The system features an integrated 100-position electronic autosampler, enabling laboratories to process multiple samples in an organized and automated sequence.
The large sample capacity helps reduce manual intervention and allows users to set up extended analytical sequences, making the EMA 402XL well suited for laboratories handling a high volume of samples.
Key advantages include:
- 100-position electronic sample capacity
- Automated sample handling
- Reduced manual intervention
- Efficient batch analysis
- Improved laboratory productivity
- Convenient sequential sample processing
Dynamic Reagent-Free Vertical Furnace
The EMA 402XL features a dynamic, reagent-free vertical furnace capable of reaching temperatures up to 1350 °C.
The high-temperature furnace provides the conditions required for effective combustion and elemental determination. Its reagent-free configuration can help simplify laboratory operation and reduce the need for additional chemical reagents during the analytical process.
The vertical furnace design provides an efficient environment for processing large samples while supporting consistent analytical performance.
Advanced Detection Technology
The EMA 402XL uses dedicated detection technologies for different elements, providing an optimized approach to elemental quantification.
NDIR Detection for Carbon, Hydrogen and Sulfur
Carbon, Hydrogen, and Sulfur are quantified using separate NDIR (Non-Dispersive Infrared) detectors.
The use of dedicated NDIR detection provides an efficient method for measuring the relevant combustion gases generated during elemental analysis.
TCD Detection for Nitrogen
Nitrogen is measured using a Thermal Conductivity Detector (TCD).
The TCD provides reliable detection of nitrogen and complements the NDIR detection system used for carbon, hydrogen, and sulfur.
Together, these detection technologies allow the EMA 402XL to perform comprehensive CHNS elemental analysis within a single system.
Direct Analysis of Large Samples
One of the key features of the EMA 402XL is its capability to perform direct analysis of extra-large solid or liquid samples up to 3 grams.
This makes the analyzer particularly useful when working with samples that are difficult to reduce to very small quantities or when larger sample quantities are desirable for analytical purposes.
The ability to accommodate larger samples can provide greater flexibility for laboratories working with different sample types and compositions.
Applications
The VELP EMA 402XL Macro CHNS Analyzer can be used in a broad range of research and industrial applications, including:
- Chemical analysis
- Pharmaceutical research
- Food and feed analysis
- Agricultural research
- Environmental analysis
- Material characterization
- Polymer research
- Petrochemical analysis
- Organic compound analysis
- Academic research
- Industrial quality control
- Product development and formulation
Key Features
- Simultaneous CHNS elemental determination
- Designed for macro elemental analysis
- Integrated 100-position electronic autosampler
- Dynamic reagent-free vertical furnace
- Furnace temperature up to 1350 °C
- Separate NDIR detectors for Carbon, Hydrogen, and Sulfur
- TCD detection for Nitrogen
- Direct analysis of extra-large solid or liquid samples
- Supports samples of up to 3 grams
- Automated sample processing
- Designed for demanding laboratory workflows
- Suitable for research, quality control, and routine elemental analysis
Benefits for Modern Laboratories
The VELP EMA 402XL is designed to help laboratories improve analytical efficiency while accommodating larger sample quantities. Its combination of automated sample handling, high-temperature reagent-free combustion, dedicated detection technologies, and large-sample capability provides a comprehensive platform for macro CHNS elemental analysis.
The integrated autosampler supports high-throughput workflows, while the separate NDIR and TCD detection systems provide dedicated measurement capabilities for the target elements. The ability to analyze samples up to 3 grams further expands the range of materials that can be evaluated using the system.
A Powerful Solution for Macro CHNS Analysis
With its advanced configuration and large-sample capabilities, the VELP EMA 402XL Macro CHNS Analyzer provides a practical solution for laboratories requiring efficient and comprehensive determination of Carbon, Hydrogen, Nitrogen, and Sulfur.
From research and development to routine quality control and material characterization, the EMA 402XL is engineered to support demanding analytical workflows with automated sample handling, high-temperature combustion, and specialized detection technology.
The VELP EMA 402XL combines macro-sample capability, automated operation, reagent-free combustion, and advanced detection technology to provide a complete solution for professional CHNS elemental analysis.

Reviews
There are no reviews yet.